Ticket number 34352
Context NOC-NetworkServices
Ticket Status Update
Ticket Source GARR
Ticket Type Incident
Ticket open time 13/10/2026 16:55
Ticket close time
Affected Link rl1.fi01 -- rs1.rm02
rl1.rm01 -- rs1.mi02
rl1.rm04 -- rs1.bo01
rl1.rm06 -- rs1.bo01
rl2.rm04 -- rs1.bo01
rl2.rm06 -- rs1.bo01
rs1.pi01 -- rs1.rm02
rs1.rm02 -- rs1.mi02
Affected Service
Problem type Degradation
Problem description Degrado monodirezionale
Problem fixer Supplier
Problem start 13/10/2026 16:40
Problem end
Subject PI01-Torricelli -- LI00-S.Vincenzo [TrailSpan] [929526/95]
History 13/10/2026 16:55
Aperto ticket operatore
14/10/2026 08:02
Richiesti aggiornamenti
15/10/2026 08:18
Nessun riscontro ricevuto, richiesti aggiornamenti
15/10/2026 11:01
- Fibrecop in intervento - Disattivati amplificatori Raman
15/10/2026 15:55
Misure ricevute, analisi in corso
15/10/2026 16:32
Aperti ticket operatore per ispezionare i connettori IRM
16/10/2026 13:40
Richiesti aggiornamenti
19/10/2026 08:59
Sollecitato operatore
19/10/2026 09:11
Videoscopio disponibile in giornata
19/10/2026 16:20
Intervento a LI00 previsto per domani ore 11
20/10/2026 09:40
Intervento in corso, spente IRM
20/10/2026 12:48
Tecnico è intervenuto con microscopio "meccanico", richiesto di recuperare videoscopio per ispezione e export immagini
21/10/2026 11:34
Richiesti aggiornamenti a fornitore
28/10/2026 14:38
Ispezione connettori a PI01 in corso
28/10/2026 15:19
Ispezionati solo i connettori delle fibre perche' il microscopio non aveva l'adattatore per ispezionare i connettori della IRM. Chiesto di rifare l'intervento con l'adattatore
20/11/2026 11:23
Intervento previsto per martedì ore 8:30
24/11/2026 09:22
Intervento rimandato causa taglio fibra su tratta backbone parallela (tts 34582)
25/11/2026 08:08
Altro guasto rientrato, richiesto di riprendere la lavorazione
26/11/2026 09:10
intervento previsto per lunedi' 30/11 ore 8:30
Problem fix