Ticket info
| Ticket number | 32873 |
| Context | NOC-NetworkServices |
| Ticket Status | Update |
| Ticket Source | GARR |
| Ticket Type | Incident |
| Ticket open time | 12/02/2026 15:06 |
| Ticket close time | |
| Affected Link | e2e INFN - CNAF - Tecnopolo -- INFN - LNL - Legnaro - lato LNL e2e INFN - CNAF TECNOPOLO - Bologna -- INFN - LNL - Legnaro - lato Tecnopolo rs1.bo01 -- re2.mi01 rs1.bo01 -- re2.mi02 rs1.pd02 -- rs1.bo01 |
| Affected Service | e2e INFN - CNAF - Bologna - Tecnopolo -- INFN - LNL - Legnaro - lato CNAF e2e INFN - CNAF - Bologna -- INFN - LNL - Legnaro - lato LNL |
| Problem type | Fault |
| Problem description | Link down |
| Problem fixer | Supplier |
| Problem start | 12/02/2026 14:48 |
| Problem end | |
| Subject | [Link down] e2e INFN - CNAF - Bologna - Tecnopolo -- INFN - LNL - Legnaro - lato CNAF, e2e INFN - CNAF - Bologna -- INFN - LNL - Legnaro - lato LNL |
| History | 12/02/2026 15:06 Problema su circuiti trasmissivi, analisi in corso 12/02/2026 15:37 Da prime verifiche sembra esserci un problema sul nodo trasmissivo a RO00, aperta segnalazione a fornitore 12/02/2026 15:47 Link up, si tiene in monitoraggio |
| Problem fix |