Ticket info
| Ticket number | 24557 |
| Context | NOC-NetworkServices |
| Ticket Status | Close |
| Ticket Source | GARR |
| Ticket Type | Incident |
| Ticket open time | 08/09/2021 08:20 |
| Ticket close time | 22/09/2021 09:24 |
| Affected Link | INAF - OA Abruzzo - Teramo -- PoP Roma-Tizii - Backup |
| Affected Service | INAF - OA Collurania - Teramo |
| Problem type | Fault |
| Problem description | Link down |
| Problem fixer | User |
| Problem start | 08/09/2021 05:21 |
| Problem end | 21/09/2021 09:21 |
| Subject | INAF - OA Collurania - Teramo |
| History | 08/09/2021 08:20 Indagini in corso 09/09/2021 12:25 Richiesto riavvio antenna e media converter 21/09/2021 09:12 Verifiche in corso 21/09/2021 09:46 Link up In attesa di sostituzione del PoE Injector lato Università |
| Problem fix | Riavviato PoE |